MICiTECH 10-Liter High-Flow Stationary Oxygen Concentrator (CP101): A Complete Guide
A high-capacity concentrator built around a heavy-duty double-wobble compressor — continuous flow from 1.0 to 10.0 LPM, a compact 44.6 lb chassis, and a rated 15,000+ hour compressor lifespan.
High-flow oxygen equipment lives or dies on compressor durability — a unit that can’t sustain non-stop operation becomes a maintenance liability fast. The MICiTECH 10-Liter Stationary Oxygen Concentrator (Model CP101) is built around a heavy-duty compressor rated specifically for that kind of continuous demand.
Delivering continuous-flow oxygen from 1.0 to 10.0 LPM at 93% (±3%) purity, the CP101 pairs an oil-free double-wobble compressor rated for 15,000 to 18,000 operational hours with imported lithium molecular sieve beds that reach full concentration within 60 seconds of startup.
Distributed by Compass Health Brands
The CP101 is distributed under the MICiTECH brand by Compass Health Brands (Roscoe Medical) and backed by a 3-year limited compressor and sieve bed warranty. As a Class II FDA-regulated medical device, it is available strictly by prescription.
MICiTECH CP101 10-Liter Concentrator
MICiTECH 10-Liter High-Flow Stationary Oxygen Concentrator
A high-capacity, clinical-grade oxygen system engineered for continuous, non-stop operation in long-term care facilities, hospitals, and residential care environments. Delivers continuous flow from 1.0 to 10.0 LPM with linear 93% (±3%) purity, powered by an oil-free double-wobble compressor rated for 15,000 to 18,000 operational hours. Imported lithium molecular sieve beds reach full concentration within 60 seconds of startup. An integrated microprocessor continuously tracks purity, pressure, and internal temperature, triggering alarms for low purity (below 82%), power failure, cycle faults, and thermal overload. Compact cabinet with a top handle and 4 locking casters for easy movement through narrow doorways.
Complete Spec Sheet
| Specification | Detail |
|---|---|
| Brand / Distributor | MICiTECH / Compass Health Brands (Roscoe Medical) |
| Model / SKU | CP101 (UPC 860012953332) |
| Classification | High-Flow Stationary Oxygen Concentrator |
| FDA Status | Class II Medical Device — Prescription (Rx) Required |
| HCPCS Code | E1390 |
| Flow Range | 1.0–10.0 LPM Continuous Flow (electronic flowmeter) |
| Oxygen Concentration | 93% (±3%) |
| Outlet Pressure | 8.7–11.6 PSI |
| Power | AC 110–120V / 60 Hz (~700W continuous draw) |
| Sound Level | ≤ 55 dBA average |
| Dimensions | 21.26"H x 15.74"L x 11.81"W |
| Weight | ~44.6 lbs (20.5 kg) |
| Warranty | 3-Year Limited Compressor & Sieve Bed Warranty |
Clinical Selection Note: The CP101 must be plugged directly into a grounded 3-prong wall outlet — extension cords or power strips are not supported, and backup generators must provide pure sine-wave output with at least 1,500W surge capacity. Always cross-reference device capabilities with your physician’s prescription.
Who Is the MICiTECH CP101 Typically Prescribed For?
The CP101 is well suited to high-flow patients whose prescribed rate falls within the 1–10 LPM range, in long-term care facilities, hospitals, and residential care settings running equipment continuously around the clock. Its rated compressor lifespan and compact chassis make it a fit for facilities looking to reduce equipment replacement cycles while minimizing storage floor space. As with any high-flow device, the appropriate flow rate should be determined by your physician based on your specific prescription.
Adding the MICiTECH CP101 to the EnhDme-Pro catalog gives facilities a durable, high-flow option engineered specifically for continuous, non-stop clinical use.
Frequently Asked Questions
What routine filter maintenance is required for the CP101?
Maintenance requires no tools. The rectangular cabinet pre-filter on the back should be removed weekly, washed in warm water, and air-dried completely before re-insertion. The internal intake filter capsule should be inspected every 3 to 6 months and replaced when gray discoloration appears.
What electrical supply considerations must be verified before deployment?
The CP101 draws 700 watts continuously and must be plugged directly into a grounded 3-prong wall outlet. Extension cords or retail power strips must not be used, as initial inductive current spikes can trigger power-fault alarms. Backup generators must provide pure sine-wave output with at least a 1,500W surge capacity.
What prescription documentation is required prior to order dispatch?
Per FDA Class II regulations, orders for the MICiTECH 10L Oxygen Concentrator require a valid prescription or medical license specifying continuous-flow oxygen settings prior to compliance release.