AirSep NewLife Intensity 10 LPM High-Flow Oxygen Concentrator: A Complete Guide
A high-flow, high-pressure stationary concentrator built for hospitals and specialty respiratory care — continuous flow up to 10 LPM at 20 PSIG, available in single-flow or dual-patient configurations.
High-acuity patients on accessory-driven oxygen therapy — jet nebulizers, venti-masks, tracheostomy setups — need more than just high flow; they need the pressure to drive that equipment directly. The AirSep NewLife Intensity 10 is built for exactly that combination.
Delivering continuous-flow oxygen from 2.0 to 10.0 LPM at an elevated 20 PSIG outlet pressure — roughly three times standard home concentrator pressure — the NewLife Intensity 10 is available in both single-flow and dual-patient configurations to fit hospitals, long-term care facilities, and specialty respiratory care networks.
Engineered by AirSep / CAIRE Medical
The NewLife Intensity 10 is manufactured by AirSep / CAIRE Medical and backed by a 3-year limited manufacturer warranty. As a Class II FDA-regulated medical device (21 CFR Part 807), it is available strictly by prescription.
AirSep NewLife Intensity 10
AirSep NewLife Intensity 10 High-Flow Oxygen Concentrator
A clinical-grade, high-flow and high-pressure stationary oxygen concentrator delivering continuous flow from 2.0 to 10.0 LPM at 20 PSIG outlet pressure — sufficient to drive large-volume jet nebulizers, medication nebulizers, venti-masks, and tracheostomy setups directly, without a separate air compressor, and to maintain delivery through tubing runs up to 200 feet. Built around an oversized, industrial-grade compressor and sieve bed assembly rated for continuous 24/7/365 operation. Includes an integrated solid-state oxygen monitor with alarms for power failure, pressure faults, and high temperature. Available in single-flow (AS099-101) or dual-flow (AS099-4) configurations, with the concentrator core, sieve bed matrix, and 20 PSIG pressure identical across both.
Single Flow vs. Dual Flow
The concentrator core, internal sieve bed matrix, and 20 PSIG outlet pressure are identical across both configurations — the difference is flowmeter count and patient capacity.
| Configuration | MPN / SKU | Flowmeter Count | Clinical Capacity |
|---|---|---|---|
| Single Flow | AS099-101 | One Flowmeter | Up to 10.0 LPM for a single high-acuity patient |
| Dual Flow | AS099-4 | Two Independent Flowmeters | Serves two patients concurrently (combined max 10 LPM); full 20 PSIG to each output |
Because single- and dual-flow units carry different HCPCS descriptors (E1390 vs. E1391), standardizing purchase orders by configuration simplifies downstream billing reconciliation.
Complete Spec Sheet
| Specification | Detail |
|---|---|
| Brand / Manufacturer | AirSep / CAIRE Medical |
| Model | NewLife Intensity 10 (AS099-101 Single / AS099-4 Dual) |
| Classification | High-Flow & High-Pressure Stationary Oxygen Concentrator |
| FDA Status | Class II Medical Device (21 CFR Part 807) — Prescription (Rx) Required |
| HCPCS Code | E1390 (Single Flow AS099-101) / E1391 (Dual Flow AS099-4) |
| Flow Range | 2.0–10.0 LPM Continuous Flow |
| Outlet Pressure | 20 PSIG (138 kPa) |
| Oxygen Purity | Up to ~95.5% (90% ±3% at 10 LPM max) |
| Sound Level | ~55 dBA |
| Dimensions | 27.5"H x 16.5"W x 14.5"D |
| Weight | ~58.0 lbs (26.3 kg) |
| Power / Altitude | 120 VAC / 60 Hz (~590W average) | max altitude 10,000 ft |
| Warranty | 3-Year Limited Manufacturer Concentrator Warranty |
Clinical Selection Note: Equipment must be selected according to prescribed flow rate and delivery requirements. Always cross-reference device capabilities with your physician’s prescription.
Who Is the NewLife Intensity 10 Typically Prescribed For?
The NewLife Intensity 10 is well suited to high-acuity patients requiring accessory-driven respiratory therapies — jet nebulizers, venti-masks, tracheostomy care — where the 20 PSIG output provides the pneumatic force to run that equipment directly. The dual-flow configuration also suits shared or semi-private rooms, letting one unit serve two patients concurrently and reducing device count, floor space, and power-outlet demand compared to deploying two single-flow units. As with any high-flow device, the appropriate flow rate and configuration should be determined by your physician based on your specific prescription.
Adding the NewLife Intensity 10 to the EnhDme-Pro catalog gives facilities a high-flow, high-pressure option built to drive clinical accessories directly, in either single- or dual-patient configurations.
Frequently Asked Questions
What prescription documentation is required prior to order dispatch?
Per FDA Class II medical device regulations, a valid prescription from a licensed healthcare practitioner specifying oxygen flow settings must be verified prior to order shipment release.
How does the dual-flow configuration affect HCPCS billing versus the single-flow unit?
HCPCS E1391 (dual delivery port) applies when two beneficiaries share one concentrator; per CMS guidance, only one beneficiary’s claim should reflect the code for that shared unit. HCPCS E1390 (single delivery port) applies to the standard single-flow configuration (AS099-101).
What clinical accessories can this unit power directly?
The 20 PSIG outlet pressure — roughly three times a standard concentrator — is sufficient to drive large-volume jet nebulizers, medication nebulizers, venti-masks, and tracheostomy setups without requiring a separate auxiliary air compressor.