{"product_id":"sequal-eclipse-5-portable-oxygen-concentrator","title":"Sequal Eclipse 5 Portable Oxygen Concentrator","description":"\u003cstyle\u003e\n    .enhdme-pro-container { font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Arial, sans-serif; max-width: 900px; margin: 0 auto; padding: 2rem 1rem; color: #1a1a2e; line-height: 1.6; }\n    .enhdme-pro-container h1 { font-size: 2rem; color: #1a1a2e; margin-bottom: 0.5rem; line-height: 1.25; }\n    .enhdme-pro-subtitle { font-size: 1.1rem; color: #4a5568; margin-bottom: 1.5rem; font-weight: 500; }\n    \n    \/* Quick Specs Grid for B2B Procurement *\/\n    .enhdme-pro-quick-specs { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 0.75rem; background: #f8fafc; border: 1px solid #cbd5e1; border-radius: 8px; padding: 1rem; margin-bottom: 2rem; }\n    .enhdme-pro-spec-card { background: #ffffff; padding: 0.75rem; border-radius: 6px; border: 1px solid #e2e8f0; }\n    .enhdme-pro-spec-card .label { font-size: 0.8rem; text-transform: uppercase; letter-spacing: 0.05em; color: #64748b; font-weight: 700; display: block; margin-bottom: 0.25rem; }\n    .enhdme-pro-spec-card .value { font-size: 0.95rem; color: #0f172a; font-weight: 600; margin: 0; }\n    .enhdme-pro-spec-card .value a { color: #1a6bbf; text-decoration: underline; }\n    \n    .enhdme-pro-container h2 { font-size: 1.4rem; color: #1a1a2e; margin-top: 2rem; margin-bottom: 0.75rem; border-bottom: 2px solid #e2e8f0; padding-bottom: 0.4rem; }\n    .enhdme-pro-container h3 { font-size: 1.15rem; color: #0f172a; margin-top: 1.5rem; margin-bottom: 0.5rem; font-weight: 700; }\n    .enhdme-pro-container p { font-size: 1.05rem; color: #334155; margin-bottom: 1rem; }\n    .enhdme-pro-container ul { margin-bottom: 1.5rem; padding-left: 1.25rem; }\n    .enhdme-pro-container li { margin-bottom: 0.5rem; font-size: 1.05rem; color: #334155; }\n    \n    \/* Technical Specification Table *\/\n    .enhdme-pro-spec-table { width: 100%; border-collapse: collapse; margin: 1.25rem 0 1.75rem; font-size: 1rem; }\n    .enhdme-pro-spec-table th, .enhdme-pro-spec-table td { padding: 0.75rem 1rem; text-align: left; border-bottom: 1px solid #e2e8f0; }\n    .enhdme-pro-spec-table th { background-color: #f8fafc; color: #0f172a; font-weight: 600; width: 35%; }\n    .enhdme-pro-spec-table td { color: #334155; }\n\n    \/* Procurement Highlight Callout *\/\n    .enhdme-pro-insight-box { background-color: #f0f6ff; border-left: 4px solid #1a6bbf; padding: 1.25rem; margin: 2rem 0; border-radius: 0 8px 8px 0; }\n    .enhdme-pro-insight-box h3 { font-size: 1.1rem; color: #1a6bbf; margin: 0 0 0.5rem 0; text-transform: uppercase; letter-spacing: 0.03em; font-weight: 700; }\n    .enhdme-pro-insight-box p { margin: 0; font-size: 1rem; color: #1e3a8a; }\n\n    \/* FAQ Section *\/\n    .enhdme-pro-faq-section { background: #ffffff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1.5rem; margin-top: 2rem; }\n    .enhdme-pro-faq-item { margin-bottom: 1.25rem; }\n    .enhdme-pro-faq-item:last-child { margin-bottom: 0; }\n    .enhdme-pro-faq-item p strong { color: #0f172a; font-size: 1.05rem; display: block; margin-bottom: 0.25rem; }\n    .enhdme-pro-faq-item p { margin: 0; font-size: 1rem; color: #475569; }\n\n    \/* Warnings \u0026 Disclaimers *\/\n    .enhdme-pro-prop65-box { background-color: #fffaf0; border: 1px solid #ffeacc; padding: 1rem; margin: 1.5rem 0; font-size: 0.95rem; color: #7c2d12; border-radius: 6px; }\n    .enhdme-pro-prop65-box strong { color: #c05621; }\n    .enhdme-pro-disclaimer { font-size: 0.9rem; color: #64748b; margin-top: 1.5rem; font-style: italic; }\n\n    @media (max-width: 600px) {\n        .enhdme-pro-quick-specs { grid-template-columns: 1fr 1fr; }\n        .enhdme-pro-spec-table th, .enhdme-pro-spec-table td { display: block; width: 100%; padding: 0.5rem 0; }\n        .enhdme-pro-spec-table tr { border-bottom: 1px solid #cbd5e1; padding-bottom: 0.5rem; display: block; margin-bottom: 0.5rem; }\n        .enhdme-pro-spec-table th { background: transparent; padding-bottom: 0.1rem; }\n    }\n\u003c\/style\u003e\n\n\u003cdiv class=\"enhdme-pro-container\"\u003e\n    \u003ch1\u003eCAIRE SeQual Eclipse 5 Portable Oxygen Concentrator\u003c\/h1\u003e\n    \u003cdiv class=\"enhdme-pro-subtitle\"\u003eDual-Mode Transportable System | Continuous Flow up to 3.0 LPM \u0026amp; Pulse Settings 1–9 | autoSAT® Technology\u003c\/div\u003e\n\n    \u003c!-- Quick Specs Grid for B2B Procurement --\u003e\n    \u003cdiv class=\"enhdme-pro-quick-specs\"\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eDelivery Modes\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eContinuous (0.5–3.0 LPM) \u0026amp; Pulse (Settings 1–9)\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003ePulse Output\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eUp to 192 mL Bolus Delivery\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eSmart Technology\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eautoSAT® \u0026amp; UltraSense® Breath Triggering\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eCompliance Mandate\u003c\/span\u003e\n            \u003cp class=\"value\"\u003e\u003ca href=\"https:\/\/enhdme-pro.com\/pages\/prescription-policy\"\u003eRx Required (FDA Class II)\u003c\/a\u003e\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ch2\u003eExecutive Product Overview\u003c\/h2\u003e\n    \u003cdiv class=\"enhdme-pro-body-content\"\u003e\n        \u003cp\u003eThe CAIRE SeQual Eclipse 5 (Model 6900-SEQ) is an industry-standard dual-mode transportable oxygen concentrator engineered to deliver continuous-flow medical oxygen up to 3.0 LPM and pulse-dose oxygen across settings 1 through 9 (up to a 192 mL bolus). Designed for 24\/7\/365 clinical reliance, the Eclipse 5 bridges the gap between stationary bedside concentrators and lightweight ambulatory portables.\u003c\/p\u003e\n        \u003cp\u003eEquipped with CAIRE's proprietary autoSAT® technology, the Eclipse 5 automatically adjusts internal compressor performance to maintain constant oxygen volume delivery even as patient respiratory rates fluctuate during physical exertion. Featuring UltraSense® technology for high-sensitivity breath detection, the unit operates on AC, 12V DC vehicle power (charging continuously at 2.0 LPM continuous or all pulse settings), and battery power. Fully FAA-approved for commercial air travel, it ships complete with a telescoping travel cart, accessory bag, and AC\/DC adapters.\u003c\/p\u003e\n\n        \u003ch3\u003eKey Performance \u0026amp; Operational Features\u003c\/h3\u003e\n        \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eTrue Dual Delivery Capabilities:\u003c\/strong\u003e Continuous flow from 0.5 to 3.0 LPM (in 0.5 LPM increments) plus pulse dosing settings 1 to 9 (up to 192 mL bolus).\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003ePatented autoSAT® Technology:\u003c\/strong\u003e Servos output to match dynamic breathing rates, maintaining linear arterial oxygen saturation margins.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eUltraSense® Breath Triggering:\u003c\/strong\u003e High-sensitivity pressure sensor detects subtle inspiratory effort with fast valve response times.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003e24\/7\/365 Operational Duty Rating:\u003c\/strong\u003e Engineered for continuous home bedside deployment and mobile transport.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eDC Vehicle Power Recharging:\u003c\/strong\u003e Full operational and battery charging capability when plugged into 12V DC vehicle sockets (at 2.0 LPM continuous and all pulse settings).\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eFAA Commercial Aviation Approved:\u003c\/strong\u003e Conforms to Federal Aviation Administration guidelines for commercial aircraft deployment.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Telescoping Cart:\u003c\/strong\u003e Includes an adjustable transport cart with oversized wheels for smooth navigation across uneven terrain.\u003c\/li\u003e\n        \u003c\/ul\u003e\n\n        \u003ch3\u003eComplete Technical Specifications\u003c\/h3\u003e\n        \u003ctable class=\"enhdme-pro-spec-table\"\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eBrand \/ Manufacturer\u003c\/th\u003e\n                    \u003ctd\u003eCAIRE® Inc. \/ Chart Industries\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eModel Designation\u003c\/th\u003e\n                    \u003ctd\u003eSeQual Eclipse 5 (SKU: 6900-SEQ)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eProduct Classification\u003c\/th\u003e\n                    \u003ctd\u003eDual-Mode Transportable Oxygen Concentrator\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eFDA Regulatory Status\u003c\/th\u003e\n                    \u003ctd\u003eClass II Medical Device | Prescription (Rx) Required\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eHCPCS Billing Code\u003c\/th\u003e\n                    \u003ctd\u003eE1390 (Concentrator) \/ E1392 (Portable Concentrator)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eDelivery Output Scope\u003c\/th\u003e\n                    \u003ctd\u003eContinuous: 0.5–3.0 LPM | Pulse Dose: Settings 1.0–9.0 (Up to 192 mL)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eOxygen Purity \u0026amp; Sound\u003c\/th\u003e\n                    \u003ctd\u003e90% (+5.5% \/ -3.0%) Purity | Sound Level: 40 dBA (Pulse 3) \/ 48 dBA (3 LPM Cont.)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\n                    \u003ctd\u003e19.3″ H x 12.3″ W x 7.1″ D | Net Weight: 18.4 lbs (8.3 kg) with battery installed\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003ePower Capabilities\u003c\/th\u003e\n                    \u003ctd\u003eAC 100–240V (50\/60Hz); DC 12V; Rechargeable Li-Ion (~2 to 5 hr recharge per battery)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eIncluded Accessories\u003c\/th\u003e\n                    \u003ctd\u003eConcentrator, 1 power cartridge battery, telescoping cart, accessory bag, AC\/DC cords, cannula\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eWarranty Coverage\u003c\/th\u003e\n                    \u003ctd\u003e3-Year Concentrator \u0026amp; Sieve Bed \/ 1-Year Battery Warranty\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Procurement Insight Callout --\u003e\n    \u003cdiv class=\"enhdme-pro-insight-box\"\u003e\n        \u003ch3\u003eFacility Procurement \u0026amp; Risk Mitigation Insight\u003c\/h3\u003e\n        \u003cp\u003eProcuring the CAIRE SeQual Eclipse 5 solves complex transport logistics for clinical facilities. Supplying continuous flow up to 3.0 LPM alongside pulse dosing up to setting 9, it allows care teams to support both active ambulation and nocturnal PAP sleep integration with a single mobilizable asset, reducing overall fleet diversity overhead.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- FAQ Section --\u003e\n    \u003cdiv class=\"enhdme-pro-faq-section\"\u003e\n        \u003ch2\u003eProduct \u0026amp; Compliance FAQs\u003c\/h2\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between continuous flow and pulse dose delivery on the Eclipse 5?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: Continuous flow delivers an uninterrupted stream of medical oxygen measured in Liters Per Minute (0.5–3.0 LPM), required for sleep therapy or high-acuity needs. Pulse dose delivers breath-actuated oxygen boluses synchronized with inspiratory triggering (Settings 1–9) to preserve battery power during ambulation.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: How does CAIRE's autoSAT® technology support fluctuating patient respiratory rates?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: autoSAT® functions as an automated throttle control. As a patient's breathing rate increases during activity or ambulation, autoSAT® automatically adjusts compressor cycle timing to ensure the full prescribed oxygen bolus is delivered without drop-offs.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: What prescription documentation is required prior to order dispatch?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: Per FDA Class II medical device regulations, orders for the CAIRE SeQual Eclipse 5 require a valid prescription or medical license specifying continuous or pulse-dose oxygen settings prior to compliance verification and shipment release.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"enhdme-pro-disclaimer\"\u003eB2B Procurement Disclaimer: Technical specifications, flow ratings, and regulatory billing descriptors (HCPCS E1390\/E1392) are compiled from CAIRE Inc. manufacturer standards. Facilities are responsible for verifying valid prescription documentation prior to patient deployment.\u003c\/p\u003e\n\n    \u003cdiv class=\"enhdme-pro-prop65-box\"\u003e\n        \u003cp\u003e\u003cstrong\u003e⚠ WARNING:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to \u003ca rel=\"noopener\" href=\"https:\/\/www.P65Warnings.ca.gov\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Caire","offers":[{"title":"Default Title","offer_id":46258029854777,"sku":"6900-SEQ","price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/7823\/0841\/files\/caire-eclipse-5-landing-page_png.webp?v=1785305559","url":"https:\/\/enhdme-pro.com\/products\/sequal-eclipse-5-portable-oxygen-concentrator","provider":"EnhDme-Pro","version":"1.0","type":"link"}