{"product_id":"drive-devilbiss-chad-oxymizer-disposable-oxygen-conserver-pendant-style-case-of-24","title":"Drive Devilbiss Chad Oxymizer Disposable Oxygen Conserver (Pendant Style) (Case Of 24)","description":"\u003cstyle\u003e\n    .enhdme-pro-container { font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Arial, sans-serif; max-width: 900px; margin: 0 auto; padding: 2rem 1rem; color: #1a1a2e; line-height: 1.6; }\n    .enhdme-pro-container h1 { font-size: 2rem; color: #1a1a2e; margin-bottom: 0.5rem; line-height: 1.25; }\n    .enhdme-pro-subtitle { font-size: 1.1rem; color: #4a5568; margin-bottom: 1.5rem; font-weight: 500; }\n    \n    \/* Quick Specs Grid for B2B Procurement *\/\n    .enhdme-pro-quick-specs { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 0.75rem; background: #f8fafc; border: 1px solid #cbd5e1; border-radius: 8px; padding: 1rem; margin-bottom: 2rem; }\n    .enhdme-pro-spec-card { background: #ffffff; padding: 0.75rem; border-radius: 6px; border: 1px solid #e2e8f0; }\n    .enhdme-pro-spec-card .label { font-size: 0.8rem; text-transform: uppercase; letter-spacing: 0.05em; color: #64748b; font-weight: 700; display: block; margin-bottom: 0.25rem; }\n    .enhdme-pro-spec-card .value { font-size: 0.95rem; color: #0f172a; font-weight: 600; margin: 0; }\n    \n    .enhdme-pro-container h2 { font-size: 1.4rem; color: #1a1a2e; margin-top: 2rem; margin-bottom: 0.75rem; border-bottom: 2px solid #e2e8f0; padding-bottom: 0.4rem; }\n    .enhdme-pro-container h3 { font-size: 1.15rem; color: #0f172a; margin-top: 1.5rem; margin-bottom: 0.5rem; font-weight: 700; }\n    .enhdme-pro-container p { font-size: 1.05rem; color: #334155; margin-bottom: 1rem; }\n    .enhdme-pro-container ul { margin-bottom: 1.5rem; padding-left: 1.25rem; }\n    .enhdme-pro-container li { margin-bottom: 0.5rem; font-size: 1.05rem; color: #334155; }\n    \n    \/* Technical Specification Table *\/\n    .enhdme-pro-spec-table { width: 100%; border-collapse: collapse; margin: 1.25rem 0 1.75rem; font-size: 1rem; }\n    .enhdme-pro-spec-table th, .enhdme-pro-spec-table td { padding: 0.75rem 1rem; text-align: left; border-bottom: 1px solid #e2e8f0; }\n    .enhdme-pro-spec-table th { background-color: #f8fafc; color: #0f172a; font-weight: 600; width: 35%; }\n    .enhdme-pro-spec-table td { color: #334155; }\n\n    \/* Procurement Highlight Callout *\/\n    .enhdme-pro-insight-box { background-color: #f0f6ff; border-left: 4px solid #1a6bbf; padding: 1.25rem; margin: 2rem 0; border-radius: 0 8px 8px 0; }\n    .enhdme-pro-insight-box h3 { font-size: 1.1rem; color: #1a6bbf; margin: 0 0 0.5rem 0; text-transform: uppercase; letter-spacing: 0.03em; font-weight: 700; }\n    .enhdme-pro-insight-box p { margin: 0; font-size: 1rem; color: #1e3a8a; }\n\n    \/* FAQ Section *\/\n    .enhdme-pro-faq-section { background: #ffffff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1.5rem; margin-top: 2rem; }\n    .enhdme-pro-faq-item { margin-bottom: 1.25rem; }\n    .enhdme-pro-faq-item:last-child { margin-bottom: 0; }\n    .enhdme-pro-faq-item p strong { color: #0f172a; font-size: 1.05rem; display: block; margin-bottom: 0.25rem; }\n    .enhdme-pro-faq-item p { margin: 0; font-size: 1rem; color: #475569; }\n\n    \/* Warnings \u0026 Disclaimers *\/\n    .enhdme-pro-prop65-box { background-color: #fffaf0; border: 1px solid #ffeacc; padding: 1rem; margin: 1.5rem 0; font-size: 0.95rem; color: #7c2d12; border-radius: 6px; }\n    .enhdme-pro-prop65-box strong { color: #c05621; }\n    .enhdme-pro-disclaimer { font-size: 0.9rem; color: #64748b; margin-top: 1.5rem; font-style: italic; }\n\n    @media (max-width: 600px) {\n        .enhdme-pro-quick-specs { grid-template-columns: 1fr 1fr; }\n        .enhdme-pro-spec-table th, .enhdme-pro-spec-table td { display: block; width: 100%; padding: 0.5rem 0; }\n        .enhdme-pro-spec-table tr { border-bottom: 1px solid #cbd5e1; padding-bottom: 0.5rem; display: block; margin-bottom: 0.5rem; }\n        .enhdme-pro-spec-table th { background: transparent; padding-bottom: 0.1rem; }\n    }\n\u003c\/style\u003e\n\n\u003cdiv class=\"enhdme-pro-container\"\u003e\n    \u003ch1\u003eDrive DeVilbiss CHAD Oxymizer Disposable Oxygen Conserver — Pendant Style (Case of 24)\u003c\/h1\u003e\n    \u003cdiv class=\"enhdme-pro-subtitle\"\u003eHigh-Flow Fluidic Oxygen Conserving Device | 4:1 Conservation Ratio | Model P-224 (24\/Case)\u003c\/div\u003e\n\n    \u003c!-- Quick Specs Grid for B2B Procurement --\u003e\n    \u003cdiv class=\"enhdme-pro-quick-specs\"\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eConservation Ratio\u003c\/span\u003e\n            \u003cp class=\"value\"\u003e4:1 Savings (Reduces Gas Use up to 75%)\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eMax Input Flow\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eUp to 15.0 LPM High-Flow Input\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eCase Packaging\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eCase of 24 Individually Wrapped Units\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-spec-card\"\u003e\n            \u003cspan class=\"label\"\u003eCompliance Mandate\u003c\/span\u003e\n            \u003cp class=\"value\"\u003eOver-The-Counter (OTC — No Rx Required)\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ch2\u003eExecutive Product Overview\u003c\/h2\u003e\n    \u003cdiv class=\"enhdme-pro-body-content\"\u003e\n        \u003cp\u003eThe Drive DeVilbiss CHAD Oxymizer Disposable Oxygen Conserver (Model P-224) is a non-electronic, fluidic oxygen-conserving nasal device engineered for continuous high-flow oxygen therapy. Operating without batteries, electronic logic circuits, or moving mechanical switches, the Oxymizer utilizes a close-coupled 20 mL internal reservoir pouch situated on the chest pendant to capture oxygen during the exhalation phase and release a highly concentrated bolus at the exact onset of inhalation.\u003c\/p\u003e\n\n        \u003cp\u003eAchieving up to a 4:1 oxygen conservation savings ratio, the P-224 reduces overall cylinder and liquid oxygen consumption by up to 75%. The pendant configuration positions the primary reservoir lower on the chest, making it easily concealable under clothing while eliminating face weight for improved patient comfort. Capable of accommodating continuous flow rates up to 15 LPM, it connects directly to standard oxygen sources including stationary concentrators, compressed gas cylinders, and liquid oxygen reservoirs.\u003c\/p\u003e\n\n        \u003ch3\u003eKey Performance \u0026amp; Operational Features\u003c\/h3\u003e\n        \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003e100% Battery-Free Fluidic Logic:\u003c\/strong\u003e Mechanical pulse operation eliminates low-battery failures, charging cords, and electronic sensor weight.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003e4:1 Oxygen Conservation Ratio:\u003c\/strong\u003e Delivers equivalent clinical oxygenation at reduced flow settings, extending portable tank duration up to four times longer.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eDiscreet Pendant Reservoir Housing:\u003c\/strong\u003e Positions the 20 mL storage chamber on the chest neck-loop for comfortable, weight-free facial wear that hides under shirts.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHigh-Flow Accommodations (Up to 15 LPM):\u003c\/strong\u003e Safely handles high continuous input rates for difficult-to-saturate clinical patients.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eUniversal Oxygen Source Integration:\u003c\/strong\u003e Standard 6-foot connection line hooks directly to concentrators, compressed gas cylinders, and liquid oxygen systems.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eComfortable Latex-Free Construction:\u003c\/strong\u003e Soft medical-grade clear silicone nasal prongs prevent skin breakdown during extended wear.\u003c\/li\u003e\n        \u003c\/ul\u003e\n\n        \u003ch3\u003eComplete Technical Specifications\u003c\/h3\u003e\n        \u003ctable class=\"enhdme-pro-spec-table\"\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eBrand \/ Manufacturer\u003c\/th\u003e\n                    \u003ctd\u003eDrive DeVilbiss Healthcare (CHAD Therapeutics)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eModel Designation \/ SKU\u003c\/th\u003e\n                    \u003ctd\u003eP-224 (Case of 24 Units)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eGTIN \/ Case Barcode\u003c\/th\u003e\n                    \u003ctd\u003e50822383274503\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eHCPCS Billing Code\u003c\/th\u003e\n                    \u003ctd\u003eE1353 (Oxygen Accessory — Conserving Device)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eRegulatory \u0026amp; Prescriptive Tier\u003c\/th\u003e\n                    \u003ctd\u003eFDA Registered Class I Medical Accessory | OTC (No Rx Required)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eMaximum Input Flow Limit\u003c\/th\u003e\n                    \u003ctd\u003eUp to 15.0 Liters Per Minute (LPM)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eConservation Efficiency\u003c\/th\u003e\n                    \u003ctd\u003eUp to 4:1 Savings Ratio (Saves up to 75% gas volume)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eReservoir Volume Capacity\u003c\/th\u003e\n                    \u003ctd\u003e20 mL Internal Chest Pouch\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eTubing Length \u0026amp; Material\u003c\/th\u003e\n                    \u003ctd\u003e6-Foot Flexible Connection Tube | Medical-Grade Silicone (Latex-Free)\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003cth\u003eUsage \u0026amp; Replacement Cycle\u003c\/th\u003e\n                    \u003ctd\u003eDisposable | Recommended replacement every 3 weeks (or when moisture accumulates)\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Procurement Insight Callout --\u003e\n    \u003cdiv class=\"enhdme-pro-insight-box\"\u003e\n        \u003ch3\u003eFacility Procurement \u0026amp; Risk Mitigation Insight\u003c\/h3\u003e\n        \u003cp\u003eStandardizing high-flow oxygen care on the Drive DeVilbiss CHAD Oxymizer P-224 extends portable compressed gas supply life by up to 400%, lowering institutional gas refill expenditures and cylinder delivery frequency. Because it requires no inline electronic controllers or batteries, it provides reliable high-flow oxygen conservation without electronic fault risks.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- FAQ Section --\u003e\n    \u003cdiv class=\"enhdme-pro-faq-section\"\u003e\n        \u003ch2\u003eProduct \u0026amp; Compliance FAQs\u003c\/h2\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: What is the main design difference between the P-224 (Pendant) and F-224 (Mustache) Oxymizer models?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: Both models deliver an identical 4:1 conservation ratio. The F-224 Mustache model features a storage reservoir sitting directly over the upper lip, whereas the P-224 Pendant model moves the 20 mL reservoir down to a weighted medallion sitting over the chest, concealing the reservoir under clothing and removing weight from the patient's nose.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: Can an inline humidifier bottle be used with the Oxymizer P-224?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: No. Water humidifiers or active bubble bottles must not be used inline with the Oxymizer. Excess water vapor condenses inside the 20 mL chest reservoir pouch, causing the internal fluidic membrane to stick and rendering the conservation mechanism ineffective.\u003c\/p\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"enhdme-pro-faq-item\"\u003e\n            \u003cp\u003e\u003cstrong\u003eQ: How frequently should the Oxymizer P-224 be replaced?\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp\u003eA: The P-224 is a disposable accessory. It should be replaced every 3 weeks, or sooner if natural exhalation moisture accumulates noticeably inside the chest pouch and interferes with gas delivery.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cp class=\"enhdme-pro-disclaimer\"\u003eB2B Procurement Disclaimer: Technical specifications, conservation ratios, and regulatory billing descriptors (HCPCS E1353) are compiled from Drive DeVilbiss Healthcare standards. Facilities are responsible for verifying appropriate clinical application prior to deployment.\u003c\/p\u003e\n\n    \u003cdiv class=\"enhdme-pro-prop65-box\"\u003e\n        \u003cp\u003e\u003cstrong\u003e⚠ WARNING:\u003c\/strong\u003e This product can expose you to chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to \u003ca rel=\"noopener\" href=\"https:\/\/www.P65Warnings.ca.gov\" target=\"_blank\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drive Medical","offers":[{"title":"Default Title","offer_id":46257994498105,"sku":"P-224-CASE","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0811\/7823\/0841\/files\/P-224.jpg?v=1785303930","url":"https:\/\/enhdme-pro.com\/products\/drive-devilbiss-chad-oxymizer-disposable-oxygen-conserver-pendant-style-case-of-24","provider":"EnhDme-Pro","version":"1.0","type":"link"}